Draft Simulator - DDSM1

The Fieldpiece Voltage Accessory, model AVH1, is designed for use with our data logger model DL3 to record voltage over a period of time or with our EHDL1 electronic handle to get the MIN or Max while freeing up your meter for other tests.User's Manual

Product Flyer

Package Art

Competitive Advantages

What's Included?

Recommended

 

 

 

 

 

 

Pressure switches are often out of calibration before they completely fail, and it is for a wide variety of reasons --  all of which can cause the furnace to operate in an unsafe manner.

The DDSM1 Draft Simulator creates a controlled vacuum to test pressure switches, so technicians can tell exactly when a pressure switch closes and opens.  This either proves that the switch is within specification, or identifies if the switch is starting to fail.  

Plus, the DDSM1 is the only tool able to calibrate adjustable pressure switches to manufacturers’ specifications.  This saves contractors from carrying a large inventory of pressure switches on their trucks, and from leaving the job site to buy pre-calibrated switches.

  • Easily Calibrate Any Adjustable Pressure Switch
  • Always have the Right Pressure Switch on your Truck
  • No Need to Carry a Wide Variety of Pressure Switches
  • Mimics  Pressure Produced by Live Draft Inducers
  • Replaces Unreliable “Checking” Procedures
  • Reduces Call Backs

Competitive Advantages

A pressure switch is a safety device that prevents furnaces from running in unsafe conditions.  Until the DDSM1 Draft Simulator came to market, there were no safe, accurate, and reliable ways to test pressure switches.

Now HVACR professionals can test pressure switches to see if they are failing, and can calibrate adjustable pressure switches to furnace specifications, so there's no need to carry a wide variety of switches on their truck, or need to leave the job site to go purchase a pre-calibrated pressure switch.

What's Included


  • Draft Simulator - DDSM1
  • One set of test leads
  • Two hoses
  • Two hose adapters
  • Operator’s manual

AVH1-SRC-product-tmb


Recommended Accessories and Replacement Parts

The SDMN5 is a portable, rugged dual-port manometer designed especially for HVAC/R field service. Measures gas pressure, static pressure and pressure differential.

Dual-Port Manometer – SDMN5

The SDMN5 is a portable, rugged dual-port manometer designed especially for HVAC/R field service. Measures gas pressure, static pressure and pressure differential. The SDMN5 includes a zero adjust button of the face of the meter, a rugged rubber boot, a magnet on the back for hanging the meter during service, and the Auto Power-Off (APO) function conserves battery life. The SDMN5 measures pressure between -60inWC and 60inWC (inches of water column) and -150.0 to 150.0 mBar. The SDMN5 also measures P1 or P2 pressure readings and calculates the difference between P1 and P2. Take static pressure measurements with a resolution of 0.01inWC or 0.01mBar. Includes 3/16” to 5/16” adapter for measuring gas inlet and outlet pressures.

Read More..


Normal 0 false false false MicrosoftInternetExplorer4

Display: 3 1/2 digit liquid crystal display (LCD) with maximum reading of 1999. 

Overrange: (OL) or (-OL) is displayed.

Low battery indication: The battery symbol is displayed when the battery voltage drops below the operating level.

Measurement rate: 2.5 times per second, nominal.

Operating Environment: 0°C to 40°C at < 70% relative humidity.

Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery removed from meter.

Auto power off: 15 seconds approx.

Standby consume current: <10μA

Battery: 4 pcs 1.5V (AAA size) UM-4 R03. 

Battery Life: 4 hours (continuity) typical with alkaline battery (@20ÌÙ range test 10ÌÙ resistor). 

Dimensions: 170mm(H) x 44mm(W) x 40mm(D). 

Weight: 160g including batteries.

 

ELECTRICAL

Range: 20MW, 2000 MW.

Resolution: 10K W on 20MW range, 1 MW on 2000 MW range.

Accuracy:

20 MW range: ±(2%rdg + 2dgts)

2000 MW range: <500ÌÙ ±(4%rdg + 2dgts)

>500 MW ±(5%rdg + 2dgts)

Rated voltage: DC-DC converter to 1000VDC

Accuracy temperature: 23°C ± 5°C less than 70%RH

Temperature Coefficient: 0.1X (specified accuracy)/°C (28°C)