Furnace testing excellence.
Gas, static, and differential pressure
Test pressure switches
Easily calibrate any adjustable pressure switch
Great for diagnosing furnace performance
The Dual Port Manometer has the ranges to measure gas pressure and the resolution needed to measure static pressure. Ideal for HVACR field service technicians, the SDMN6 can determine if the gas pressure coming into the house or out of the regulator are correct. The SDMN6 measures gas pressure up to 60″ water column (WC) with a resolution of 0.1″ WC. In addition, the unit measures both positive and negative pressure, which is used for measurement on vacuum control lines. The unit will take differential pressure readings and display the difference between P1 and P2 at all times in the lower right corner of the easy-to-read LCD. Four different measurement scales can be used: inches of water column, millimeters of water column, mBar, and PSI.
The SDMN6 also has a zero adjust to zero out the meter in different ambient pressures. It has a hold button to hold the currently displayed reading. The auto-power-off function conserves battery life, but can be disabled if desired.
In the static pressure mode, the unit can measure up to 2″WC with resolution to 0.010″WC, which enables a technician to measure small differences in air (or static) pressure.
Includes:
Specifications
Take out the battery hold the power button for 45 seconds and reinstall battery. If this does not work the first time try again. If it sill won’t turn on check to see if you have a good battery or call fieldpiece for an RMA.
The pump in the SDMN6 is very sensitive and the increase button or decrease button needs to be pressed multiple times before you will see a change in the pump.